Self-regulating heating cable HTSB

07-584C-…..
Features
- Self-regulating
- Steam purging possible
- Wide operating temperature range
- Can be used in explosive atmospheres without temperature limiter
- Simple installation thanks to its high flexibility
- Outer protective fluoropolymer jacket ensures resistance to corrosion and chemical influences
Certification
Ambient temperature
Max. continuous operating temperature,
energized +250°C
Max. continuous exposure temperature,
de-energized +250°C
Refer to the documentation for more detailed information
Description
A temperature-dependant resistive element between two parallel copper conductors regulates the power output of the heating cable. This output regulation is carried out automatically along the entire length of the heating cable according to the prevailing ambient temperature. If the ambient temperature rises, the power output of the cable is reduced.
This self-regualating property prevents overheating even when the cables are crossed. Thanks to the parallel design the heating cable can be cut to any required length. This feature considerably simplifies project planning and installation. The heating cable is cut and terminated directly on the construction site according to the circumstances. The heating system must be designed to ensure that the maximum exposure temperature of +250 °C will not be exceeded when it is energized.