Limit switch


07-2511-..../..
Certification
EPS 14 ATEX 1 766 X
IECEx EPS 14.0092X
CCC 2020322304000843
NEPSI GYJ17.1067X
EAC RU C-DE.BH07.B.04162/22
SC 20.0567 X
KCS KTL 17-KA4BO-0623X (GAS)
KCS KTL 17-KA4BO-0624X (Dust)
Marking
ATEX: II 2G Ex db IIC T6, T5 Gb
II 2D Ex tb IIIC T80°C, T95°C Db
IECEx:
Ex db IIC T6, T5 Gb
Ex tb IIIC T80°C, T95°C Db
Guidelines/Norms
EN 60947-5-1
EN 60947-1
Ambient temperature
T6 up to max. +75 °C
depending on the rated current
Description
The limit switches have been developed for Ex-areas where safe and reliable signalling is required, for example on pumps, petrol pumps, as well as in mechanical and high-tec engineering.
The switches must be mounted into the respective devices or systems in such a way as to guarantee mechanical protection. No further tests are required. The connection cable is cast in on the back of the switch. For the connection in Ex-areas BARTEC provides a large variety of terminals and terminal boxes.
Technical data *
Protection class | IP 66 (IEC 60529) |
Dimensions | see data sheet |
Material | plastic (thermoplastics), plunger/additional actuator: stainless steel |
Contact material | Silver or gold-coated contacts (all contact elements have a standard protective gold-coating as standard) |
Mechanical life | > 2 x 106 switching cycles |
Weight | with 3 m cable: single-break switch 210 g, double-break switch 415 g |
Voltage | see data sheet |
Current | see data sheet |
*Refer to the documentation for more detailed information