Attention: Our e-mail addresses with the domain bartec-benke.de has changed to bartec.com!

Flameproof Flashing Lights
TNFCD and TNFCDM


Features
- Seawater-resistant
- External trigger
- Siren card available
- Wide temperature range
- Multiple dome colors
Marking
TNFCD: II 2G Ex d IIC T4 Gb or Ex de IIC T4 Gb
TNFCDM: II 2G Ex d IIC T4 Gb
Guidelines/Norms
EN/IEC: 60079-0, 60079-1, 60079-7
EN: 50281-1-1
Ambient temperature
-50 °C to +60 °C (-58 °F to +140 °F)
Description
BARTEC TECHNOR’s TNFCD/M series is an extreme duty fl ash beacon solution for use in hazardous location on- or off shore. Designed for the most demanding environments of the North Sea, the beacons have for more than 25 years proven their excellence, providing a low maintenance solution for operators and rig owners worldwide. Available in Ex de, Ex d or non-Ex. The beacon off ers a multiple of options like power on when connected, external trigging or a siren card for acoustic warning.
Technical data *
Protection class | IP66 (IP67 upon request) |
Material | TNFCD/TNFCDM: stainless steel 316L/CF-3M Dome colours: red, yellow, blue, green, orange, clear Surface treatment SS316L: machined/shot blasted |
Weight | TNFCD: 5.1 kg (11,2 lbs) TNFCDM: 2.5 kg (5.5 lbs) |
Energy | Flash energy TNFCD: 10 joule Flash energy TNFCDM: 5 joule |
Frequency | Flash frequency: 1 Hz |
*Refer to the documentation for more detailed information