Cable entries


07-92**-****/*****
Features
- Ex e terminal boxes are
dispensed with - Suitable for cables with
1 to max. 25 cores - Sleeves from M 16 x 1.5 to M 48 x 1.5
- Compact, space-saving design
- The cores are connected directly to the electrical load at the Ex d side, intermediate terminal positions are dispensed with
- Rated insulation voltage of up to
1000 V for small dimensions - Permanent heat resistance
up to +110°C
Certification
IECEx EPS 17.0051U
IECEx EPS 17.0050X
EPS 17 ATEX 1100 U
EPS 17 ATEX 1099 X
CML 21UKEX1855U
CML 21UKEX1854X
CCC 2020322313000663
Marking
Cable entry screwable:
ATEX: II 2G Ex d IIC T6 - T4 Gb
IECEx:
Ex d IIC T6 bis T4 Gb
Cable entry pluggable:
ATEX: II 2G Ex d IIC Gb
II 2D Ex tb IIIC Db
IECEx:
Ex d IIC Gb
Ex tb IIIC Db IP 6X
Guidelines/Norms
EN 60079-0, EN 60079-1, EN 60079-31
Ambient temperature
Working temperature: -60 °C to +110 °C
depending on the lead used (temperature ranges apply to “fixed installation“ of leads)
Ambient temperature depending on the design and the leads
Description
Flameproof Ex d cable entries are elements which allow electrical cables to be introduced into an Ex d enclosure, without danger of explosion. The additional Ex e terminal housing is not required. A main distribution box may by used or the connections can be made outside the Ex-zone. The cable entry consists of a threaded metal sleeve, in which a sheathed cable is anchored and encapsulated. The individual cores are then connected directly inside the flameproof enclosure. The length of cores and cables are customer-tailored. All cables come with standard green-yellow earth leads. The length of engaged thread between the sleeve and the flameproof “d“ enclosure must comply with DIN EN 60079-0: 2006 and DIN EN 60079-1.
Technical data *
Dimensions | see data sheet |
Installation | screwable, pluggable Sleeve size: metric: M24 x 1.5 to M48 x 1.5 non-threaded: ∅ 22 mm to ∅ 36 mm Sleeve material: Metal, bare, varnished or galvanised |
Voltage | Rated voltage: 300 V/500 V/750 V/1000 V |
Current | 6 A to 488 A (see data sheet) |
Connection | Cores depending on the working temperature and voltage - Ölflex® 100, Ölflex® 110 - HO7RN-F, Ozoflex-Plus - radiation cross-linked polyolefin copolymer - NSSHÖU max. number of cores in shielded cable: - threaded: 25 cores - non-threaded: 47 cores Cross-section: 0.25 mm² to 150 mm² |
*Refer to the documentation for more detailed information
Documentation
Data Sheet - Cable entries
UK-Declaration of Conformity - 01-9200-7CU001 - Type 07-920*-****/**** to 07-924*-****/****
UK-Declaration of Conformity - 01-9200-7CU003 - Type 07-925*-****/**** to 07-929*-****/****
Customer requirements - Cable entries/line bushings
Operational Instruction Cable entries Type 07-925.-..../.... to 07-929.-..../....
Operational Instruction Cable Entry Type 07-92..-..../.U.. and 07-92..-..../.D..
Operational Instruction Cable Entry Type 07-920.-..../.... to 07-924.-..../....