Temperature Monitoring

Temperature Monitoring - Request Offer

Select the components:
 
 
Processor Units
   
MSSP00R0PCAROBT1 - SSP without PFM
Sensor Signal Processor without Protection Filter Modul:
power supply (DC 9 to 36V), ABS enclosure (IP65, 200 x 150 x 77mm), LED indicator,
relay output alarm/fault (9-50V, 50W), serial interface (RS 232/422)
pieces  
MSRG00R0PCAROBT1 - SRG without PFM
Signal Response Generator without Protection Filter Modul:
power supply (DC 9 to 36V), ABS enclosure (IP65, 200 x 150 x 77mm), LED indicator,
relay output (alarm/fault), 8 relay outputs (free) (9-50V, 50W), 8 inputs,
serial interface (RS 232/422)
pieces  
MSSP10R0PCAROBT1 - SSP with Internal PFM
Sensor Signal Processor with Protection Filter Modul:
power supply (DC 9 to 36V), ABS enclosure (IP65, 200 x 150 x 77mm), LED indicator,
relay output alarm/fault (9-50V, 50W), serial interface (RS 232/422)
pieces  
MSRG10R0PCAROBT1 - SRG with Internal PFM
Signal Response Generator with Protection Filter Modul:
power supply (DC 9 to 36V), ABS enclosure (IP65, 200 x 150 x 77mm), LED indicator,
relay output (alarm/fault), 8 relay outputs (free) (9-50V, 50W), 8 inputs,
serial interface (RS 232/422)
pieces  
MRCU00R0PCAROBT1 - RCU
Reaction Caracterization Unit: ABS enclosure (IP65, 200 x 150 x 77mm),
32 relay outputs (9-50V, 50W), 4 inputs
pieces  
       
Cable Modules
   
MCTM00R0PEFGRBT1 - CTM
Cable Terminator Module (terminates the lines)
ABS enclosure (138 x 75 x 56 mm, IP 65)
pieces  
MCFM00R0PEFGRBT1 - CFM
Connector Filter Module (connects sensor cable and access cable segments)
ABS enclosure (138 x 75 x 56 mm, IP 65)
pieces  
MPFM00R0PEFGRBT1 - PFM
Protection Filter Module (protection against lightning sources,
connects sensor cable to access cable)
ABS enclosure (138 x 75 x 56 mm, IP 65)
pieces  
MECB0000PEFGRBT1 - ECB
Earth Connection Box (protection against lightning)
ABS enclosure (138 x 75 x 56 mm, IP 65)
pieces  
MCTM00A0PEFGRBT1 - CTM for zone 2 II 3GD Ex nA II T6
Cable Terminator Module (terminates the lines) for zone 2
ABS enclosure (138 x 75 x 56 mm, IP 65)
pieces  
MCFM00A0PEFGRBT1 - CFM for zone 2 II 3GD Ex nA II T6
Connector Filter Module (connects sensor cable and access cable segments) for zone 2
ABS enclosure (138 x 75 x 56 mm, IP 65)
pieces  
MMBI0003 - Modbus Full-Duplex
Modbus Schnittstelle RS485
pieces  
MMBI0103 - Modbus Half-Duplex
Modbus Schnittstelle RS485
pieces  
       
Cable Standard
   
CTS020R0PURROBT1 - Sensor cable - 2m sensor spacing
Operating temp. -55°C - +110°C; sheath: polyurethane, RAL 3000 red, 6.0 x 14.0 mm
meters  
CTS040R0PURROBT1 - Sensor cable - 4m sensor spacing
Operating temp. -55°C - +110°C; sheath: polyurethane, RAL 3000 red, 6.0 x 14.0 mm
meters  
CTS070R0PURROBT1 - Sensor cable - 7m sensor spacing
Operating temp. -55°C - +110°C; sheath: polyurethane, RAL 3000 red, 6.0 x 14.0 mm
meters  
CTS100R0PURROBT1 - Sensor cable - 10m sensor spacing
Operating temp. -55°C - +110°C; sheath: polyurethane, RAL 3000 red, 6.0 x 14.0 mm
meters  
CTS200R0PURROBT1 - Sensor cable - 20m sensor spacing
Operating temp. -55°C - +110°C; sheath: polyurethane, RAL 3000 red, 6.0 x 14.0 mm
meters  
CTS020B0PURROBT1 - Sensor cable - 2m sensor spacing - zone 1 - II 2G/D Ex em II T6
Operating temp. -55°C - +110°C; sheath: polyurethane, RAL 3000 red, 6.0 x 14.0 mm
meters  
CTS040B0PURROBT1 - Sensor cable - 4m sensor spacing - zone 1 - II 2G/D Ex em II T6
Operating temp. -55°C - +110°C; sheath: polyurethane, RAL 3000 red, 6.0 x 14.0 mm
meters  
CTS070B0PURROBT1 - Sensor cable - 7m sensor spacing - zone 1 - II 2G/D Ex em II T6
Operating temp. -55°C - +110°C; sheath: polyurethane; RAL 3000 red, 6.0 x 14.0 mm
meters  
CTS100B0PURROBT1 - Sensor cable - 10m sensor spacing - zone 1 - II 2G/D Ex em II T6
Operating temp. -55°C - +110°C; sheath: polyurethane; RAL 3000 red, 6.0 x 14.0 mm
meters  
CTS200B0PURROBT1 - Sensor cable - 20m sensor spacing - zone 1 - II 2G/D Ex em II T6
Operating temp. -55°C - +110°C; sheath: polyurethane; RAL 3000 red, 6.0 x 14.0 mm
meters  
CTS020A0PURROBT1 - Sensor cable - 2m sensor spacing - zone 2 - II 3G/D Ex nA II T6
Operating temp. -55°C - +110°C; sheath: polyurethane; RAL 3000 red, 6.0 x 14.0 mm
meters  
CTS040A0PURROBT1 - Sensor cable - 4m sensor spacing - zone 2 - II 3G/D Ex nA II T6
Operating temp. -55°C - +110°C; sheath: polyurethane; RAL 3000 red, 6.0 x 14.0 mm
meters  
CTS070A0PURROBT1 - Sensor cable - 7m sensor spacing - zone 2 - II 3G/D Ex nA II T6
Operating temp. -55°C - +110°C; sheath: polyurethane; RAL 3000 red, 6.0 x 14.0 mm
meters  
CTS100A0PURROBT1 - Sensor cable - 10m sensor spacing - zone 2 - II 3G/D Ex nA II T6
Operating temp. -55°C - +110°C; sheath: polyurethane; RAL 3000 red, 6.0 x 14.0 mm
meters  
CTS200A0PURROBT1 - Sensor cable - 20m sensor spacing - zone 2 - II 3G/D Ex nA II T6
Operating temp. -55°C - +110°C; sheath: polyurethane; RAL 3000 red, 6.0 x 14.0 mm
meters  
       
Accessories
   
VAC001 - USB-RS232
Serial interface RS 232, converter
pieces  
VAC003 - USB-RS422
Serial interface RS422, converter
pieces  
VCA010 - CCA Access Cable
Connect SSP with PFM
pieces  
VAC020 - Mounting Clamps - 100 pcs.
1 pieces per meter
pieces  
VAC026 - Silicagel bag - 1pc.
Filter- and absorption material
pieces  
VAC100 - Power Supply 85-264V/24V 1A - RailDIN
 
pieces  
VAC102 - Power Supply 100-240V/24V 0.9A - Hekatron "VDS"
 
pieces  
VAC090 - Mounting Tool
Tool for installation
pieces  
       
Integration Hard-Software

 
   
PTMON0001 - Visual. Software for 1-8 SSP o. SRG
Visualization of temperature, system status and alarm location
pieces  
PRGCC0002 - Config. Software - Basic
RGCC: Red Guard Control Centre Basic
pieces  
PRGCC0003BT1 - Config. Software - Professional
RGCC: Red Guard Control Centre Professional; license fee per CPU
pieces  
       

Details / specification:

Sender information:

Company*:

Department:

Name*:

Street and P.O. Box*:

Zip Code*:

City*:

Country:

E-mail*:

Phone*:

Fax:

 

* mandatory field

Data protection notice – The information you transmit to us, e.g. name, address and phone number, will be processed by us for no other purpose than for taking up direct contact to you or for any other purpose for which you transmit your data to us. At any time you can revoke the right to use the data. After the expiry of the fixed purpose, we will delete your data in accordance with the requirements of the Federal Data Protection Act unless it is subject to a statutory retention period. For more detailed information or if you have any further questions, please contact our data protection officer Mrs Kerstin Blossey dataprotection@bartec.de.
 

             

Overview

System Design

System Components

 

News

Contact Person

Request Information

Dates

Download

Applications