Select the components:
|
|
Processor Units
 |
|
|
| |
MSSP00R0PCAROBT1 - SSP without PFM
Sensor Signal Processor without Protection Filter Modul:
power supply (DC 9 to 36V), ABS enclosure (IP65, 200 x 150 x 77mm), LED indicator,
relay output alarm/fault (9-50V, 50W), serial interface (RS 232/422) |
pieces |
|
| |
MSRG00R0PCAROBT1 - SRG without PFM
Signal Response Generator without Protection Filter Modul:
power supply (DC 9 to 36V), ABS enclosure (IP65, 200 x 150 x 77mm), LED indicator,
relay output (alarm/fault), 8 relay outputs (free) (9-50V, 50W), 8 inputs,
serial interface (RS 232/422) |
pieces |
|
| |
MSSP10R0PCAROBT1 - SSP with Internal PFM
Sensor Signal Processor with Protection Filter Modul:
power supply (DC 9 to 36V), ABS enclosure (IP65, 200 x 150 x 77mm), LED indicator,
relay output alarm/fault (9-50V, 50W), serial interface (RS 232/422) |
pieces |
|
| |
MSRG10R0PCAROBT1 - SRG with Internal PFM
Signal Response Generator with Protection Filter Modul:
power supply (DC 9 to 36V), ABS enclosure (IP65, 200 x 150 x 77mm), LED indicator,
relay output (alarm/fault), 8 relay outputs (free) (9-50V, 50W), 8 inputs,
serial interface (RS 232/422) |
pieces |
|
| |
MRCU00R0PCAROBT1 - RCU
Reaction Caracterization Unit: ABS enclosure (IP65, 200 x 150 x 77mm),
32 relay outputs (9-50V, 50W), 4 inputs |
pieces |
|
| |
|
|
|
Cable Modules
 |
|
|
| |
MCTM00R0PEFGRBT1 - CTM
Cable Terminator Module (terminates the lines)
ABS enclosure (138 x 75 x 56 mm, IP 65) |
pieces |
|
| |
MCFM00R0PEFGRBT1 - CFM
Connector Filter Module (connects sensor cable and access cable segments)
ABS enclosure (138 x 75 x 56 mm, IP 65) |
pieces |
|
| |
MPFM00R0PEFGRBT1 - PFM
Protection Filter Module (protection against lightning sources,
connects sensor cable to access cable)
ABS enclosure (138 x 75 x 56 mm, IP 65) |
pieces |
|
| |
MECB0000PEFGRBT1 - ECB
Earth Connection Box (protection against lightning)
ABS enclosure (138 x 75 x 56 mm, IP 65) |
pieces |
|
| |
MCTM00A0PEFGRBT1 - CTM for zone 2 II 3GD Ex nA II T6
Cable Terminator Module (terminates the lines) for zone 2
ABS enclosure (138 x 75 x 56 mm, IP 65) |
pieces |
|
| |
MCFM00A0PEFGRBT1 - CFM for zone 2 II 3GD Ex nA II T6
Connector Filter Module (connects sensor cable and access cable segments) for zone 2
ABS enclosure (138 x 75 x 56 mm, IP 65) |
pieces |
|
| |
MMBI0003 - Modbus Full-Duplex
Modbus Schnittstelle RS485 |
pieces |
|
| |
MMBI0103 - Modbus Half-Duplex
Modbus Schnittstelle RS485 |
pieces |
|
| |
|
|
|
Cable Standard
 |
|
|
| |
CTS020R0PURROBT1 - Sensor cable - 2m sensor spacing
Operating temp. -55°C - +110°C; sheath: polyurethane, RAL 3000 red, 6.0 x 14.0 mm |
meters |
|
| |
CTS040R0PURROBT1 - Sensor cable - 4m sensor spacing
Operating temp. -55°C - +110°C; sheath: polyurethane, RAL 3000 red, 6.0 x 14.0 mm |
meters |
|
| |
CTS070R0PURROBT1 - Sensor cable - 7m sensor spacing
Operating temp. -55°C - +110°C; sheath: polyurethane, RAL 3000 red, 6.0 x 14.0 mm |
meters |
|
| |
CTS100R0PURROBT1 - Sensor cable - 10m sensor spacing
Operating temp. -55°C - +110°C; sheath: polyurethane, RAL 3000 red, 6.0 x 14.0 mm |
meters |
|
| |
CTS200R0PURROBT1 - Sensor cable - 20m sensor spacing
Operating temp. -55°C - +110°C; sheath: polyurethane, RAL 3000 red, 6.0 x 14.0 mm |
meters |
|
| |
CTS020B0PURROBT1 - Sensor cable - 2m sensor spacing - zone 1 - II 2G/D Ex em II T6
Operating temp. -55°C - +110°C; sheath: polyurethane, RAL 3000 red, 6.0 x 14.0 mm |
meters |
|
| |
CTS040B0PURROBT1 - Sensor cable - 4m sensor spacing - zone 1 - II 2G/D Ex em II T6
Operating temp. -55°C - +110°C; sheath: polyurethane, RAL 3000 red, 6.0 x 14.0 mm |
meters |
|
| |
CTS070B0PURROBT1 - Sensor cable - 7m sensor spacing - zone 1 - II 2G/D Ex em II T6
Operating temp. -55°C - +110°C; sheath: polyurethane; RAL 3000 red, 6.0 x 14.0 mm |
meters |
|
| |
CTS100B0PURROBT1 - Sensor cable - 10m sensor spacing - zone 1 - II 2G/D Ex em II T6
Operating temp. -55°C - +110°C; sheath: polyurethane; RAL 3000 red, 6.0 x 14.0 mm |
meters |
|
| |
CTS200B0PURROBT1 - Sensor cable - 20m sensor spacing - zone 1 - II 2G/D Ex em II T6
Operating temp. -55°C - +110°C; sheath: polyurethane; RAL 3000 red, 6.0 x 14.0 mm |
meters |
|
| |
CTS020A0PURROBT1 - Sensor cable - 2m sensor spacing - zone 2 - II 3G/D Ex nA II T6
Operating temp. -55°C - +110°C; sheath: polyurethane; RAL 3000 red, 6.0 x 14.0 mm |
meters |
|
| |
CTS040A0PURROBT1 - Sensor cable - 4m sensor spacing - zone 2 - II 3G/D Ex nA II T6
Operating temp. -55°C - +110°C; sheath: polyurethane; RAL 3000 red, 6.0 x 14.0 mm |
meters |
|
| |
CTS070A0PURROBT1 - Sensor cable - 7m sensor spacing - zone 2 - II 3G/D Ex nA II T6
Operating temp. -55°C - +110°C; sheath: polyurethane; RAL 3000 red, 6.0 x 14.0 mm |
meters |
|
| |
CTS100A0PURROBT1 - Sensor cable - 10m sensor spacing - zone 2 - II 3G/D Ex nA II T6
Operating temp. -55°C - +110°C; sheath: polyurethane; RAL 3000 red, 6.0 x 14.0 mm |
meters |
|
| |
CTS200A0PURROBT1 - Sensor cable - 20m sensor spacing - zone 2 - II 3G/D Ex nA II T6
Operating temp. -55°C - +110°C; sheath: polyurethane; RAL 3000 red, 6.0 x 14.0 mm |
meters |
|
| |
|
|
|
Accessories
 |
|
|
| |
VAC001 - USB-RS232
Serial interface RS 232, converter |
pieces |
|
| |
VAC003 - USB-RS422
Serial interface RS422, converter |
pieces |
|
| |
VCA010 - CCA Access Cable
Connect SSP with PFM |
pieces |
|
| |
VAC020 - Mounting Clamps - 100 pcs.
1 pieces per meter |
pieces |
|
| |
VAC026 - Silicagel bag - 1pc.
Filter- and absorption material |
pieces |
|
| |
VAC100 - Power Supply 85-264V/24V 1A - RailDIN
|
pieces |
|
| |
VAC102 - Power Supply 100-240V/24V 0.9A - Hekatron "VDS"
|
pieces |
|
| |
VAC090 - Mounting Tool
Tool for installation |
pieces |
|
| |
|
|
|
Integration Hard-Software
|
|
|
| |
PTMON0001 - Visual. Software for 1-8 SSP o. SRG
Visualization of temperature, system status and alarm location |
pieces |
|
| |
PRGCC0002 - Config. Software - Basic
RGCC: Red Guard Control Centre Basic |
pieces |
|
| |
PRGCC0003BT1 - Config. Software - Professional
RGCC: Red Guard Control Centre Professional; license fee per CPU |
pieces |
|
| |
|
|
|