Local control stations
Local control stations
Modules for front installation with connecting cable
Modules for panel-mounted installation with terminals
Actuating elements
Accessoires
|
Potentiometer for local control stations |
| |
 07-3373-1D.0
| | | Certification | PTB 05 ATEX 1064 U
| | Ex protection type | II 2G Ex de IIC
I M2 Ex de I Class I, Zone 1, AEx d IIC/Ex d IIC, T6 Class I, Division 2, Groups A, B, C, D
| | Ambient temperature | | -55 °C up to +60 °C |
|
| Technical data (Extract)(For detailed information please click here) |
|---|
| Protection class | Determined by actuating element and control station enclosure, Terminals: IP 20 (IEC 60529) |
| Material | Thermoplastic |
| Contact material | carbon film on ceramics |
| Mechanical life | > 25000 sinusoidal cycles |
| Storage temperature | -55 °C to +70 °C |
| Weight | approx. 88 g |
| Voltage | max. AC/DC 320 V |
| Power | max. 1 W |
| Resistance | 1 kΩ to 10 kΩ |
| Connection | Double terminals 2 x 2.5 mm², fine stranded |